Neutralizing Products

Contact Us

Page Contents

Neutralizers:

Neutralizing Mats/Wipes:

Neutralizing Spill Kits:

*ortho-Phthalaldehyde


Printable PDF file of this pagePrintable version of this page (PDF)
 

Home

Toxic Vapor Monitors

Neutralizing Products

Real-time Gas Monitoring

Safety Products

Bar Code Labels

Links of Interest

View Price Lists

Order Form for existing customers only

Site Search  
Site Search Engine 



Corporate Office:

Kem Medical Products

75 Price Parkway

Farmingdale, NY 11735

Phone: (800) 553-0330 or(631) 454-6565

Fax: (631) 454-8083

Glutaraldehyde and OPA Neutralizers

 

Glutaraldehyde and OPA Neutralizer - Powder

Kem-Sure Neutralizer PowderEliminate toxic vapors created during disposal of waste solution.

Dissolves easily into solution.

Will not stain soaking containers, sinks, etc. Prevents black staining.

Within 5 minutes neutralization is complete, and the solution is ready
for safe disposal. 

Safe for use in automatic scopes washers.

Glycine based, meets California Senate Bill 2035.

Available in six convenient sizes. 

  • Quart
  • 1 Gallon
  • 2 Gallons
  • 5 Gallons
  • 6 Gallons
  • 8 Gallons

1 quart glutaraldehyde/OPA neutralizations:

  • #9075-Q (24/case) one container will neutralize one (1) quart

PDF #9075-Q  -  Instructions For Use  - -  MSDS9144.pdfMSDS

KemSafeNeutralizationAndDisposalLog-powder.pdfNeutralization And Disposal Log

1 Gallon glutaraldehyde/OPA neutralizations:

  • #9075 (24/case) one container will neutralize one (1) gallon
  • #9075-12 (12/box) one container will neutralize one (1) gallon

PDF #9075 - Instructions For Use  - -  MSDS9144.pdfMSDS

KemSafeNeutralizationAndDisposalLog-powder.pdfNeutralization And Disposal Log

2 Gallon glutaraldehyde/OPA neutralizations:

  • #9075-2-8 (8/box) one container will neutralize two (2) gallons

PDF #9075-2-8 - Instructions For Use  - -  MSDS9144.pdfMSDS

KemSafeNeutralizationAndDisposalLog-powder.pdfNeutralization And Disposal Log

5 Gallon glutaraldehyde/OPA neutralizations:

  • #9075-G5 (6/box) one container will neutralize five (5) gallons
  • #9075-G5X (12/case) one container will neutralize five (5) gallons

PDF #9075-G5/G5X  -  Instructions For Use   - -   MSDS9144.pdfMSDS

KemSafeNeutralizationAndDisposalLog-powder.pdfNeutralization And Disposal Log

6 Gallon glutaraldehyde/OPA neutralizations:

  • #9075-G6 (6/box) one container will neutralize six (6) gallons
  • #9075-G6X (12/case) one container will neutralize six (6) gallons

PDF #9075-G6/G6X  -  Instructions For Use   - -   MSDS9144.pdfMSDS

KemSafeNeutralizationAndDisposalLog-powder.pdfNeutralization And Disposal Log

8 Gallon glutaraldehyde/OPA neutralizations:

  • #9075-G8 (6/box) one container will neutralize eight (8) gallons
  • #9075-G8X (12/case) one container will neutralize eight (8) gallons

PDF #9075-G8/G8X  -  Instructions For Use   - -   MSDS9144.pdfMSDS


KemSafeNeutralizationAndDisposalLog-powder.pdfNeutralization And Disposal Log

 

Also available in metric sizes.

  • 1/2 Liter
  • 1 Liter
  • 5 Liter
  • #9075-B (12/case) one container will neutralize 1/2 Liter
  • #9075-C (12/case) one container will neutralize 1 Liter
  • #9075-D (24/case) one container will neutralize 5 Liters


Top

 


Glutaraldehyde and OPA Neutralizer - Solution

Kem-SafeEliminate toxic vapors created during disposal of waste solution.

Each bottle will neutralize two (2) gallons
of waste glutaraldehyde/OPA solution.

Within 5 minutes neutralization is complete,
and the solution is ready for safe disposal.

Glycine based, meets California Senate Bill 2035.

Prevents black staining.

Will not stain soaking containers, sinks, etc.

Available in two packages sizes.


PDF #9074 - Instructions For Use  - -  MSDS9144.pdfMSDS

            KemSafeNeutralizationAndDisposalLog.pdfNeutralization And Disposal Log

Top

 


Formaldehyde Neutralizer - Powder

Reduce formaldehyde exposure.

Dissolves easily into solution. 

After 30 minutes neutralization is complete,
and the solution is ready for disposal.

 

PDF #9144 - Instructions For Use  - -  MSDS9144.pdfMSDS

Top

 


Glutaraldehyde and OPA Neutralizing Absorbent Mats/Wipes

Specifically designed to both absorb and neutralize
small spills of glutaraldehyde/OPA solutions.

MatsPlace under and around soaking baths.

With a plastic backing for extra protection.

Glycine based, meets California Senate Bill 2035.

Large size, approximately 170 square inches.

PDF #9076/9077 - Instructions For Use  - -  MSDS9176.pdfMSDS

Top

 


Formaldehyde Neutralizing Absorbent Mats/Wipes

MatsSpecifically designed to both absorb and neutralize
small spills of formaldehyde solutions.

With a plastic backing for extra protection.

Large size, approximately 170 square inches.

PDF #9146/9147 - Instructions For Use  - -  MSDS9476.pdfMSDS

Top

 


Glutaraldehyde and OPA Neutralizing Spill Kit

The glycine based spill kit, eliminates the need to dispose of spilled Glutaraldehyde/OPA as a hazardous waste.

Meets California Senate Bill 2035.

Each kit includes:

Kem-Safetm Neutralizer Powder
for two gallons of solution.

- Flip-top has perforations for easier
dispersal of powder over spill.
 
 


Chemsorb® Large Spill Response Pillows
- Four (4) absorbs 1/2 gal each.


 


 
One (1) pair of Nitrile gloves,

Label, and Disposal bag,

Directions with MSDS Documents.





PDF #9050 - Instructions For Use  - -  MSDS9476.pdfMSDS (Neutralizer Powder)

Top

 


Formaldehyde Neutralizing Spill Kit

A complete kit, with everything you need to neutralize spills up to 1/2 gallon.

Each kit includes:

Two(2) spill response pillows.

Each can absorb and neutralize approximately
1/4 gal.

 

 

One (1) pair of Nitrile gloves,

Label, and Disposal bag,

Directions with MSDS Documents.

 
 

PDF #9145 - Instructions For Use  - -  MSDS9476.pdfMSDS (Neutralizer Powder)

Top


California State Senate Bill #2035

The California Department of Toxic Substances Control (Cal/EPA) classify used glutaraldehyde and OPA as hazardous waste.

In 2000, California law makers passed Senate Bill - No. 2035. This allows medical facilities to treat and dispose of used glutaraldehyde and OPA without a permit, providing that:

  • The sole active chemical of the neutralizing solution is glycine.
  • The waste is generated by a medical facility during the disinfection
    of medical devices.
  • The waste is treated
    at the site where it
    was generated.

Our glutaraldehyde and OPA neutralizing products use glycine as the active neutralizing chemical.